| Interface |
7-16 DIN Male |
| Body Style |
Straight |
| Brand |
HELIAX® | Positive Stop™ |
| Mounting Angle |
Straight |
| |
| Connector Impedance |
50 ohm |
| Operating Frequency Band |
0 – 8800 MHz |
| Cable Impedance |
50 ohm |
| 3rd Order IMD, typical |
-120 dBm @ 910 MHz |
| 3rd Order IMD Test Method |
Two +43 dBm carriers |
| RF Operating Voltage, maximum (vrms) |
1415.00 V |
| dc Test Voltage |
4000 V |
| Outer Contact Resistance, maximum |
1.50 mOhm |
| Inner Contact Resistance, maximum |
0.80 mOhm |
| Insulation Resistance, minimum |
5000 MOhm |
| Average Power |
1.1 kW @ 900 MHz |
| Peak Power, maximum |
40.00 kW |
Insertion Loss, typical  |
0.05 dB |
| Shielding Effectiveness |
-110 dB |
| |
Click on image below to enlarge.
 |
| Outer Contact Attachment Method |
Ring-flare |
| Inner Contact Attachment Method |
Captivated |
| Outer Contact Plating |
Trimetal |
| Inner Contact Plating |
Silver |
| Attachment Durability |
25 cycles |
| Interface Durability |
500 cycles |
| Interface Durability Method |
IEC 61169-4:9.5 |
| Connector Retention Tensile Force |
890 N | 200 lbf |
| Connector Retention Torque |
5.42 N-m | 48.00 in lb |
| Insertion Force |
200.17 N | 45.00 lbf |
| Insertion Force Method |
IEC 61169-1:15.2.4 |
| Pressurizable |
No |
| Coupling Nut Proof Torque |
25.00 N-m | 221.27 in lb |
| Coupling Nut Retention Force |
1000.00 N | 224.81 lbf |
| Coupling Nut Retention Force Method |
MIL-C-39012C-3.25, 4.6.22 |
|
| Nominal Size |
1/2 in |
| Diameter |
35.99 mm | 1.42 in |
| Length |
68.00 mm | 2.68 in |
| Weight |
123.00 g | 0.27 lb |
|
| Operating Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature |
-55 °C to +85 °C (-67 °F to +185 °F) |
Immersion Depth  |
1 m |
| Immersion Test Mating |
Unmated |
| Immersion Test Method |
IEC 60529:2001, IP68 |
| Water Jetting Test Mating |
Unmated |
| Water Jetting Test Method |
IEC 60529:2001, IP66 |
| Moisture Resistance Test Method |
MIL-STD-202F, Method 106F |
| Mechanical Shock Test Method |
MIL-STD-202, Method 213, Test Condition I |
| Thermal Shock Test Method |
MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C |
| Vibration Test Method |
IEC 60068-2-6 |
| Corrosion Test Method |
MIL-STD-1344A, Method 1001.1, Test Condition A |
|
| Attenuation, Ambient Temperature |
20 °C | 68 °F |
| Average Power, Ambient Temperature |
40 °C | 104 °F |