]]>In the computer room, you will have a requirement for
a copper ground bar to be installed inside each computer server rack. TXM offers both 19” and 23” bus bars which can
be used on 2 post and 4 post racks. For
more information on the options of Rack Mount Bus Bars available on our e-store, follow this link below:
https://www.txmstore.com/rf-wireless-components/grounding/bus-bars/19-and-23-universal-bus-bars/
There are also additional ground bar (s) mounted on the wall of the server room that will be used to bond all the server rack ground bars together, along with the conduit bonds, air handling equipment bonds, door bonds, UPS power supply, etc. This server room ground bar (s) must in turn be bonded back to the main ground bar in your Telco room, and back to the first service disconnect in the main electrical room. There are typically requirements for dedicated 5-ohm or less grounding electrodes that must be bonded to the server room ground bar (s). TXM offers various sizes of wall mount bus bars for standard, TGB and TMGB series bus bars. TGB bus bars (Telecommunications Grounding Bar Kit) provide a common grounding point within the telecommunications room. The TGB is the attachment point for all telecommunications systems and equipment in a specific telecommunications space. Therefore, each telecommunications space through out the building should have a TGB. These are typically installed on a wall inside the data telecom room, allowing each telecommunications room to provide a common point of connection for systems and equipment bonding to ground. TMGB bus bars(Telecommunications Main Grounding Bar) are used as the foundation of the telecommunications grounding system and serve as an interface between the building's service equipment (power) ground and the telecommunications infrastructure. The TMGB also serves as a central connection point for the telecommunications bonding backbone (TBB) and equipment. There is usually only one TMGB per building.
For more
information on the options of Wall Mount Bus Bars available on our e-store,
follow this link below:
https://www.txmstore.com/das-rf-components/grounding/bus-bars/wall-mount/
You may have additional ground bars used for the bonding of the lightning protection system, back-up generator systems, electrical substations, equipment chassis, and many more. All of these ground bars and grounding systems must be bonded to each other in manner that does not cause additional problems with ground loops, resulting in harmonics and electrical interference.
In addition, TXM also offers isolation rack adapter kits, which include the rack adapters along with isolation pads, bushing nylon washers and screws. These can be used for additional ground isolation protection when mounting telecom equipment onto the racks. For more information, follow this link: https://www.txmstore.com/telecom-accessories/hardware-shelves-racking/iso-rackmount-adapters/
If you need further information or have additional questions, please contact us direct at sales@txmstore.com
]]>NEW Vented Version with High Weight Capacity
$134.00 each
Due to customer demand, TXM has now upgraded our 4 post shelves to allow more venting and
offer more weight capacity.
Depth | Adjustable:22"- 40"(Solid), 22" to 36" (Vented) |
Usable Depth | Adjustable:22" to 36" (Vented) |
Width | 19" |
Height | 1.72"(1U),3.47"(2U) |
Weight | 17lbs.(1USolid),18lbs.(2U), 13lbs.(1U Vented) |
Weight Capacity | 250lbs |
Material(s) | CRS (ColdRolled Steel) |
Color/Finish | BlackPowder Coated Finish |
Part Number | 4P-19-SHELFBK-1RU |
Please know that we are here to help in any way we can. Our team is on standby 24/7 to quote you and assist you with orders.
All stock items can ship first thing Monday morning for emergency orders.
We do keep a good supply on hand for the following:
Copper Bus Bars, Lugs, heat shrink
Fiber Solutions including enclosures, jumpers and pigtails
Racking and Hardware
Cat5e and Cat6 patch panels and cables, as well as bulk cable
RF Coax Bulk cable and jumpers, as well as cable attachment and entry products
We will do our best to get you what you need as quickly as possible in any emergency situations.
You can see our entire selection of grounding solutions below.
https://www.txmstore.com/rf-coax-cable/rf-coax-accessories/grounding/
]]>
Contaminated fiber connectors can often lead to network failures and limited insertion loss. For example, if a connector is dirty, even a small 1µ contaminant can degrade the signal by 1%, resulting in 0.05dB of insertion loss.
A larger 8µ speck of dust which is still invisible to our sight, can completely block the signal.
Dust is not the only culprit for attenuation loss on a fiber connector. Airborne contaminants, oils from our hands, and residue left by water and other solvents are also common contaminants on fiber connectors.
Not only are these contaminants more difficult to remove from the fiber connector, they also can cause damage to your networking equipment.
This can all be prevented, by using TXM’s Fiber Optic Cleaning Products. Our products will help you remove dust and contaminants so you can keep your fiber connections clean for optimal performance. TXM offers the following cleaning products:
https://www.txmstore.com/fiber-solutions/fiber-tools/fiber-cleaners/
]]>OM1 - Multimode
OM2 - Multimode
OM3 – Laser-Optimized Multimode
OM4 – Laser-Optimized Multimode
Choosing the right fiber type for your application is important. Future proofing your network design is crucial for network planning, but there is often a cost for that speed. So plan well and spend wisely.
TXM offers a wide range of fiber jumpers and options.
]]>RET stands for “Remote Electrical Tilt”. It is a part of the Antenna Interface Standards Group's (AISG) open specification for the control interface of antennas.
RET allows you remote access to make antenna position adjustments to achieve improved wireless signal for applications such as WISP and Cellular wireless network providers.
TXM’s 6-Conductor Remote Electrical Tilt (RET) / AISG compatible control cable assemblies are terminated with Male and Female DIN connectors. These cable assemblies are available in custom lengths by the foot OR by the meter.
TXM offers 6-Conductor Remote Electrical Tilt (RET)
control cable in bulk quantities. This AISG compatible
control cable is available by the foot
TXM’s AISG type 8-pin male and female connectors are superb quality
connectors designed for tough industrial jobs.
Features 8 contacts, DIN connectors with screw coupling. Equivalent to Amphenol C 091 A /B/D & Binder 423 series connectors.
These connectors can be used with 5-conductor, 6-conductor and 8-conductor AISG type cable.
]]>
Shopping for ethernet cable can be sometimes a little confusing if you are not used to the various terms that are used for the different types of cable that are available.
One common point of confusion comes when trying to decide if you need 'Solid" or "Stranded" ethernet cable. So let us try to quell some of the confusion.
Solid UTP
Solid UTP Category cables have solid insulated bare copper conductors. These cables are typically used in permanent and semi-permanent installations. They are designed for longer distance horizontal and backbone cable runs, PoE (power over Ethernet), and HD applications. Solid Category cables should not be over-flexed, bent, or twisted beyond the cable recommended specifications. All Cat5e and Cat6 solid UTP cables are designated with minimum bend radius for performance standards. Proper cable installation is essential in order to maximize the performance of the cable.
Stranded UTP
Stranded UTP Category cables have multiple strands (typically 7 strands per
conductor) of insulated bare copper conductors. These cables are typically used
for patch cords/cables connecting workstations; from wallplate outlet to patch
panel; and from patch panels to individual workstations. Because these cables
are more flexible than solid conductors, they are excellent for portable uses
and applications where repeated flexing is common.
Stranded Category Cables have a higher attenuation than solid category cables.
Depending on your application, you should restrict their use to short
distances. SCP recommends that you use stranded category cables for
applications under 6 meters/ 20 feet. We manufacture long length stranded Cat5e
and stranded Cat6 cables up to 100 ft/30 meters, but their use should be
restricted to non-HD applications.
Stranded cables are expensive to manufacture and as such are more expensive
than solid conductor cables for the equivalent length.
TXM sells both types in bulk and we also offer standard and custom patch cables for all types of situations. In addition, we offer high density patch panels.
Please visit our site for more Ethernet products below
]]>
CONNECTOR |
IMAGE |
FME/Female
|
|
FME/Male
|
|
N/Female
|
|
N/Male
|
|
SMA/Female
|
|
SMA/Male
|
|
RP (Reverse Polarity) SMA/Female
|
|
RP (Reverse Polarity) SMA/Male
|
|
F/Female
|
|
F/Male
|
|
TNC/Female
|
|
TNC/Male
|
|
mini UHF/Female
|
|
mini UHF/Male
|
Still not sure which connector you have? The side-by-side size comparison below may help:
left to right: SMA/Female, SMA/Male, FME/Male, FME/Female, N/Male, N/Female, F/Male, F/Female, TNC/Male, TNC/Female, mini UHF/Male, mini UHF/Female, RP-SMA/Male, RP-SMA/Female
]]>